Practical guide

Damper Setting vs Drag Factor: Match a RowErg’s Setup Across Machines

The damper lever controls airflow; drag factor is the PM’s measurement of flywheel deceleration. The same lever number can produce a different drag factor on another RowErg. Record both instead of treating the highest number as the best workout.

Home RowErg, SkiErg and BikeErg owners reading or setting their PM5 · 4 minute read · Published

On this page

Separate airflow, drag factor and output

Three values with different jobs
ValueWhat it describesWhat it does not establish
Damper 1–10Lever position controlling air into the fan housingNot a direct power score or a universal resistance level.
Drag factorFlywheel deceleration measured by the Performance MonitorNot your watts or a fitness ranking.
Pace/wattsMonitor feedback on work outputNot a complete explanation of technique, fatigue or health.

On a phone, scroll inside the table to read the remaining columns. Keyboard users can focus the table and use the arrow keys.

Higher damper settings let more air into the flywheel housing. The wheel slows faster between strokes, changing how the next stroke feels. Concept2 compares the damper to bicycle gearing: it changes the feel of applying work. On its air-resistance rower, pulling harder increases the resistance you feel regardless of the lever number.

This page focuses on the RowErg and other Concept2 indoor rowers using the documented PM workflow. The BikeErg has different cadence/calibration considerations; a rowing setup number is not automatically a cycling prescription.

Display the actual drag factor

  1. From the PM5 Main Menu, choose More Options.
  2. Select Display Drag Factor.
  3. Begin rowing; after a few seconds, the PM displays a drag factor.
  4. Record the value together with the damper position and the machine.
  5. If comparing another rower, obtain its actual reading instead of assuming the same lever number matches.

Concept2 says the RowErg/SkiErg monitor recalculates drag factor on each pull. Its explanation describes measuring flywheel slowdown between strokes and using that factor with flywheel speed to calculate work. This self-calibration supports comparing output across indoor rowers even when their airflow conditions differ. It is not evidence that every machine has identical maintenance condition.

Explain different feel without inventing a fault

Air temperature, elevation and lint in the flywheel housing can affect the relation between damper setting and drag factor. The manufacturer gives the example that damper 3 at home might feel like 4 on another machine. A difference is a reason to measure and document, not proof that either rower is broken.

Same lever, different reading

Two invented RowErg records show damper 3 with drag factor 110 on one machine and 100 on another.

Answer: Retain the different drag readings; do not label the setups identical because both levers say 3.

The values are hypothetical, not measurements of these machines. If you want a similar recorded setup, use each monitor’s actual drag reading while adjusting the lever, rather than claiming that a particular number is universally equivalent.

Different lever, matching drag reading

Two invented records show damper 3 and damper 4, both with drag factor 110.

Answer: The measured fan-load context is closer than the lever numbers suggest, but still record the machine and output.

Matching drag factor does not prove equal pace, power, technique or exertion. It describes one setup variable; compare the completed work results separately.

Use guidance without turning it into a universal target

Concept2 recommends starting with a damper setting of 3–5 and experimenting with feel and technique. That is the manufacturer’s general starting guidance, not an optimal setting prescribed for every reader. This guide does not supply a universal drag factor by age, sex, body weight or fitness level because the recorded sources do not establish one.

Increasing the damper to 10 does not automatically improve a score. Read pace/watts feedback for output, and keep stroke rate as a separate field. If the machine feels wrong or its readings are unstable, check current model-specific maintenance guidance rather than opening the fan cage or changing parts based on this comparison article.

Make a setup record that survives a machine change

Original example of a clearly labelled setup log
FieldHypothetical entryWhy keep it?
MachineHome RowErgDistinguishes this machine from the gym machine.
Workout targetSingle Distance 2000 mMakes the output task explicit.
Damper /drag factor3 /110Separates lever position from measured fan load.
Completed work2000 m in 8:20Provides the actual work result in this example.
Average pace2:05/500 m500 seconds×500÷2000=125 seconds.

On a phone, scroll inside the table to read the remaining columns. Keyboard users can focus the table and use the arrow keys.

In this invented record, 8:20 is 500 seconds. Over 2000 meters, the average is 125 seconds per 500 m, or 2:05. That pace is calculated from the work result, not from the damper or drag factor. Keep settings and results in separate columns so another reader can see exactly what is being compared.

Sources and further reading

  1. Concept2: All About Damper Setting and Drag FactorHow airflow, flywheel deceleration and output differ, and why machines can feel different at the same lever number.
  2. Concept2: How To Use Your PM5Official PM5 units, display, workout setup and saved-result instructions. Follow the sections relevant to your machine and workout type.