Practical guide
PM5 Battery Drain or Resetting: Check Door, Hardware and Firmware
Separate loose-battery resets from model-specific battery drain and the older hardware/firmware power issue. Check the actual PM5 information and battery-door notice before replacing parts; a single battery percentage does not diagnose the generator.
Record power behaviour and Product ID
Write whether the monitor fails to start, resets spontaneously, flickers, loses battery percentage or shows an exact error. From Product ID, retain PM hardware and firmware version and the actual machine. A rower frame production date, monitor hardware version and installed firmware are different fields. [1]
Use the maker’s battery checks with fresh appropriate D cells and the actual compartment/connection condition. Do not repeatedly reset a monitor to see whether saved history survives. If a firmware change is needed, first follow the current record-preservation and supported update instructions.
Keep the four manufacturer branches separate
| Branch | Relevant condition | Next step and limit |
|---|---|---|
| Loose batteries / resetting / flickering | Notice for rower/SkiErg PM5 units before 14 April 2015; qualifying REV A/B doors without foam. | Check notice/date/door; contact Concept2 for replacement and current firmware. |
| No power without batteries / known voltage issue | Hardware 500–599 combined with firmware 20 or 720. | Check Product ID; source resolution is firmware 22/722 or higher, using current supported release. |
| Rapid drain / generator path | Maker Resolution 1 is scoped to D/E/Dynamic and SkiErg. | Connection and generator diagnosis require the model-specific procedure/support. |
| Older rower battery-use branch | Maker Resolution 2 applies to Models A/B/C. | Use the battery/off-time context for this branch; do not apply generator expectations from newer frames. |
On a phone, scroll within the table. Keyboard users can focus it and use the arrow keys.
The troubleshooting source also links error 575 to inadequate voltage or a poorly fitting battery door, and recommends current firmware. That number does not prove every resetting monitor has the notice condition. Preserve the actual symptom and eligibility evidence.
Read boxing date, revision and foam as separate tests
The official product notice says PM5s on indoor rowers and SkiErgs manufactured before 14 April 2015 may have loose-battery problems. It uses the machine’s serial label and the first date group, described as the boxing date, to identify the unit’s age. For a date earlier than 14 April 2015, it recommends replacing the PM5 battery door even without symptoms. [2]
As an interim measure, the maker added foam between 14 April and 14 July 2015. It also says any door marked REV A or REV B without a foam pad should be replaced. Those are distinct tests: revision alone is not the complete condition, and the interim dates do not establish what is present on a modified monitor.
The official photo’s REV A marking was visually checked. Use the actual door and the notice together, and contact Concept2 customer service for its offered free replacement process. No door was requested, received or installed for this article. A monitor swapped onto an old frame can require support clarification before the frame’s date is used to date that monitor.
Do not turn the drain notes into a universal battery promise
For its A/B/C branch, Concept2 gives approximately 200 operating hours with alkaline D cells and says the monitor normally turns off within six minutes, with exceptions such as a computer connection or certain intervals. Its percentage discussion describes a particular battery-settling context, rather than a warranty that every battery chemistry and machine must decline at one fixed rate.
For D/E/Dynamic/SkiErg, the source’s generator checks have specific prerequisites and exclude the hardware 500–599 plus firmware 20/720 condition until it is updated. This guide routes that test to the actual maker procedure/support rather than asking a reader to perform hard exercise as a diagnostic step. BikeErg and StrengthErg are not included in that rower/SkiErg procedure by assumption.
Errors such as 886 or an unfinished-update 2220 have their own source instructions, including a full five-minute battery-removal period, fresh cells and subsequent settings/update completion. Retain the exact code for support instead of treating every battery symptom as the same error. This article does not carry out those procedures or guarantee data retention.
Two version-sensitive records
Case 1
A fictional PM5 reports hardware 550 and firmware 20, with no power when batteries are removed. An owner proposes immediately ordering a generator cable.
Show answer and explanation for case 1
Address the documented hardware/firmware condition through the supported current update route first.
550 is within 500–599 and firmware 20 is one of the specified versions. The source gives firmware 22/722 or higher as the resolution for that condition; the observation alone has not isolated the cable.
Case 2
A fictional actual door is marked REV B and has no foam pad. The current frame/monitor combination has uncertain age.
Show answer and explanation for case 2
Contact Concept2 about the notice’s door-revision condition and retain the uncertain age.
The notice independently includes REV A/B doors without foam. It does not require inventing a boxing date, and it does not make every later revision eligible.
Sources and further reading
- PM5 TroubleshootingConcept2 official support, full selected main text checked 16 November 2026. Full troubleshooting/product-notice mains and REV A photo read. No electrical measurements, hard-exercise generator test, battery trial, update or replacement request performed.
- PM5 Product NoticeConcept2 official support, full selected main text checked 16 November 2026. Full troubleshooting/product-notice mains and REV A photo read. No electrical measurements, hard-exercise generator test, battery trial, update or replacement request performed.