Practical guide
PM5 Stuck at Zero: Check Model Setting, Pickup Wire and Monitor
When menus work but rowing or skiing values stay at zero, first check the pickup connection. On an indoor rower, verify the configured frame model, then distinguish visible wire or port damage from a monitor fault. Do not apply the rower model-setting sequence to every erg.
Confirm the exact zero-values symptom
Concept2 describes a powered monitor whose screens can be navigated but whose numbers remain at zero when rowing or skiing. This differs from a blank monitor, missing LCD lines or a missing stored workout. Start with the cable from the machine’s generator/pickup plugged fully into the monitor. Record whether the menus respond and which values remain zero. [1]
Next identify the actual machine. The manufacturer’s model-type correction in this section is explicitly for indoor rowers. A SkiErg’s Product ID wording does not authorize selecting a rower frame setting on that machine. BikeErg and StrengthErg are not added to the rower correction by analogy.
Verify the rower model before changing parts
First inspect Main Menu → More Options → Utilities → More Utilities → Product ID and read the Model field. Only if it differs from the physical rower should you change the type. The maker notes that a SkiErg can show D/E here, while this correction procedure remains for indoor rowers.
For the current documented rower route, use Main Menu → More Options → Utilities → More Utilities → Erg Model Type. The source describes pressing Next until the model entry is reached, then Change Display/Display three times to reach the change option. Choose the correct RowErg D/E/Dynamic, C, B or A setting and confirm.
For older PM5/PM4/PM3 menus, the source instead starts from the LCD Contrast screen and uses Units three times followed by Display three times, then Change Type and Set Type. In those older menus, the source uses D or D/E for Model D, D/E for Model E/Dynamic, and C, B or A for the appropriate older frame. These are two documented interface paths, not a reason to press the same buttons on every firmware screen. If your actual menu differs, retain Product ID and ask the manufacturer.
Choose using the physical frame identity, not merely the attached monitor name. Concept2 says the model procedure may need repeating after batteries are changed. Check the resulting model entry and whether values now count; pressing the buttons without checking the output is not a completed result.
Inspect the wire/port and keep the result conditional
| Observation | Maker next branch | What remains unknown |
|---|---|---|
| Pickup plug not fully seated | Seat the documented connection and recheck values. | A seated plug alone does not prove the wire is intact. |
| Rower model entry does not match frame | Correct through the applicable documented menu. | Machine wear and wire condition remain separate. |
| Pickup wire visibly broken/frayed | Use the maker’s replacement wire route. | Do not infer monitor failure solely from the zero display. |
| Monitor port visibly cracked | Maker identifies monitor replacement branch. | Exact replacement/version still needs confirmation. |
| Known-working compatible monitor counts on this machine | Monitor-versus-wire swap is a maker isolation check. | A swap is only evidence if the comparison monitor is known to work and is correctly configured. |
On a phone, scroll within the table. Keyboard users can focus it and use the arrow keys.
If an appropriate known-working monitor is available, the source uses a swap to distinguish monitor and pickup-wire paths. The source says that if a known-working monitor also stays at zero on this machine, the pickup-wire path is faulty; if it counts normally, the original monitor is the fault branch. Record the correctly configured comparison and its actual result. Otherwise contact Concept2 with the observations; do not claim a comparison was performed merely because it could be performed.
Two worked diagnostic records
Case 1
A fictional PM5 responds to menus on a Model C frame, but its configured erg entry is D/E/Dynamic. The pickup plug is seated.
Show answer and explanation for case 1
Correct the actual rower model entry using the applicable firmware menu, then recheck counting.
The connection and model are separate checks. A mismatch supports a documented setting correction; it does not yet prove that the monitor or wire is broken.
Case 2
A fictional SkiErg has responsive menus and zero workout values. An online note tells the owner to select RowErg C.
Show answer and explanation for case 2
Do not apply the indoor-rower model-setting procedure; use the pickup/wire checks and SkiErg support.
The read source limits its type-change instruction to indoor rowers. Similar-looking Product ID labels do not extend that procedure to a different machine.
Send the actual branch result to support
Retain frame/model, monitor hardware and firmware from Product ID, exact screen behaviour, pickup seating, visible damage and any properly performed comparison result. The manufacturer also discusses internal circuit contamination; no disassembly or circuit cleaning is performed or instructed here. For supported firmware updates use the separate update-method guide and preserve needed records. A factory reset is not the first step for zero readings.
Sources and further reading
- PM5 TroubleshootingConcept2 official support, full selected main text checked 16 November 2026. Full troubleshooting main read. No physical generator test, monitor swap, circuit inspection or button diagram trial; indoor-rower model correction is explicitly scoped.